Pure Pulse Battery Maintainers/Desulfators

  Services













Pure Pulse is a unique, patented technology built into products designed to prevent and remove sulfation. Sulfation is the main cause of battery problems and failure, on all types of lead acid batteries, including flooded, AGM, VRLA, Gel and flooded cell. Eliminating sulfate buildup from lead-acid battery plates improves battery performance and extends battery life up to 3 times.

What is Sulfation?
Sulfation is the creation of lead sulfates. It is a natural and necessary part of a battery's life and occurs whenever the battery is in a state of discharge, i.e. whenever the battery is NOT charging. Over time as the battery discharges, the electrolyte solution inside the battery turns into water and the lead plates become covered with lead sulfate crystals.

As a battery ages through use or sits unused for periods of time, these lead sulfate crystals enlarge and eventually build-up to the point where they create a physical barrier across the surface of the battery plates. Before long, this build-up can become so dense that a battery is no longer able to accept or release energy.

Battery sulfation is a wasting disease that claims the life of 80 percent of the batteries in use worldwide. Don't let your battery be one of the 80% that die needlessly. 

Sulfates negatively impact battery performance by:
     Reducing the battery's ability to discharge power
     Reducing the battery's ability to recharge
     Shortening battery life


Pure Pulse Working

Pulse is delivered to the battery through a circuit which is independent of the charging circuit. This patented, high-frequency pulse waveform is of a specific amplitude and frequency that is precisely controlled by microprocessors. It rises rapidly in less than one microsecond to its maximum amplitude and gradually returns to zero. There is no abrupt stop and no battery drain. This waveform occurs 25,000 times a second and has been proven to remove sulfation from the battery plates and return the lead sulfate back to the electrolyte solution.







​                                                                    Pure Waveform

Patented waveform is simply the most effective method to remove damaging battery sulfation and enhance battery performance available today!

Data






​(Micrograph of a battery plate covered in heavy sulfation buildup (lead sulfate crystals).

Studies by major universities were conducted in response to a request from the military, scientific and engineering communities for scientific validation of claims that actually improves battery efficiency and lengthens battery life. 

During these studies, these crystalline buildups (sulfation) were regularly investigated by X-ray diffraction methods. The X-ray diffraction data confirmed the positive effects of the application of this Pure Pulse on the battery plate morphology. It shows a more even distribution of lead sulfate crystals over the surface area of the battery plates. It also revealed a significant reduction in the size of the lead-sulfate crystals These microscopic changes, kind of an electro-mechanical "stirring" or "cleaning" action on the plate surface, greatly improve a battery's ability to accept and store more energy.

During University study, testing was also done on stored batteries to determine how pure pulsation would affect military vehicles that sit unused for long periods of time. The batteries were stored at a constant temperature of 25°C (77°F) for 14 weeks.

The final report lists the following results: "There is a distinctive difference in the charge capacity between these two batteries. A battery stored under the influence of pure pulsation retained its original capacity while the capacity of the battery stored without pure pulsation lost a considerable amount of charge. The decrease of charge capacity of batteries stored without pure pulsation decreased linearly with time. 

After 14 weeks the decrease of charge capacity accounted for about 25% of the battery's original capacity. In this same period of time, the charge of the battery attached to using pulse slightly increased This is probably due to a reconditioning (reforming) process of the battery plates by continuous pulsation" .


The row of plates, charged with pure pulsation, remain free from sulfates and ensure battery performance at maximum peak capacity. Note: development of battery-killing sulfates on the conventionally charged plates.

"This evaluation indicates that many batteries previously condemned could be reclaimed if Pure Pulse were used extensively; assuming there is no internal damage to battery, i.e.: plates, etc." The report goes on to state: "In conclusion, pure pulsation worked by removing sulfation from the battery plates as the manufacturer claimed. It is unknown exactly how long a battery will last with Pure Pulse connected, but it is estimated at least eight to ten years of life can be added."

By minimizing sulfation buildup and thereby producing less resistance through the charge and discharge cycles throughout the "usable" life of a battery, the battery's life can be enhanced considerably.  Pure Pulse will prevent the larger crystals from forming allowing more room in the battery to store energy which in turn allows the battery to accept, store and release more energy.

Make no mistake – patented conditioning process is NOT pulse charging or a burst of high voltage provided within the regime. Instead, the low-voltage, high-frequency conditioning pure pulse is introduced into the battery via a separate circuit independent of the charging circuit. This precisely-controlled waveform has proven to be the best at removing sulfation from the battery plates and returning lead sulfate back to the electrolyte solution.


How Much Money Will you Save?

Although the lead-acid battery is not excessively expensive, its cost goes up dramatically when you include the cost of downtime, disposal and labor hours. These costs will be reduced or even eliminated by simply extending battery life and increasing battery efficiency. In addition, our Battery Management Program, reduces battery consumption by an average of 70%.

Environmental Impact

After the tire, the battery is the most expensive and difficult product to dispose of safely. Yet, it is estimated that over 80% of the batteries being discarded every year are only suffering from lead plates that are clogged with sulfate crystals. Imagine the contamination that prematurely dumping battery lead and sulfuric acid across the nation can cause. Then realize what difference the implementation of Pulse Technology can make. By extending battery life and improving battery efficiency, the number of batteries being prematurely discarded can be reduced considerably and the potential environmental damage can be avoided reducing both your carbon footprint and increasing adherence to corporate sustainability policies.


   Crystal Pure Power

30% Federal Tax Rebate

plus State and County Incentives

 Crystal Pure in a OEM distributor for EcoSmarte and Rain Water Hotel Systems.


 $300 - 100W RV Kit with Nuetral Ground Controller.

             expandable up to 600W, $200 per 100W.

 

 $15,000 – 6500 Watt Home Solar System.

                  25 year Solar Panel Warranty. German designed and assembled in the USA.




 $Call - ​Crystal Pure's Evaporative Water Recovery System generates pure (distilled) water using solar, geothermal or waste heat sources.  The system can operate on very narrow temperature differentials with significantly lower operation and maintenance costs than comparable systems.